PRE Checklist
Jump to navigation
Jump to search
Table 1-1. Personal Rescue Enclosure egress
PRE EGRESS | |||
---|---|---|---|
Cue card version | Expanded version | ||
PRE — RETRIEVE | Unstow PRE and PRE PLSS equipment from footlocker. | ||
CHECK O2 | Verify LiOH scrubbers in good condition and safe for use and that interior O2 canister is at 100%. | ||
PRE — INFLATE | Connect PRE to airlock AUX suit air supply system or to external tank supply via EMU suit hose. Verify communication and PLSS system okay unless on external supply. | ||
DON O2 MASK | Crewmember to don O2 mask. Verify sufficient O2 flow and PRE integrity. | ||
SEDATIVE (if reqd) | Crewmember to apply sedative patch if required. Alternatively, crew can use MP3 player or other item to remain calm in needed, provided communication with rescue crew maintained. | ||
ENTER PRE | Enter PRE and assume position. Knees should be tucked and head brought as close to knees as possible. O2 canister and CO2 scrubbers to be placed between legs. Arms should curl around knees. Tail should be curled around to the front, if able. | ||
PRE — CLOSE | Rescue crewmember will close and secure PRE by zipping the enclosure and verifying positive pressure seal. Verify no leaks. | ||
PRE — SECURE | Rescue crewmember to secure PRE to transfer tether or to suit using PRE D-clips and tether and/or caribiner. Verify PRE secure to tether/EMU.
| ||
COMM — CONNECT | Connect communication cable from PRE to EMU or external antenna. Verify secure. | ||
COMM — CHECK | Rescue crew to verify communications system between PRE and EMU are nominal and crewmember within PRE is okay. | ||
A/L — DEPRESS | Rescue crew to depressurized airlock. | ||
PRE — A/L AUX HOSE DISCONNECT | Disconnect PRE from airlock AUX O2 supply. If connected to secondary canister or EMU PLSS, skip next step.
| ||
PRE — EMU/AUX O2 TIE-IN (if reqd) | Connect PRE to secondary O2 supply via PRE suit hose ports. Connect to EMU or Constellation using buddy-hose tie-in or connect to external O2 canister. | ||
TRANSFER PRE | Rescue crew to transfer PRE to rescue Shuttle via tether or RMS. | ||
PRE — A/L AUX HOSE CONNECT | Reconnect PRE to rescue Shuttle airlock AUX O2 supply. | ||
A/L REPRESS | Repressurize rescue Shuttle airlock. | ||
COMM — DISCONNECT FROM PRE | Disconnect communications cable from PRE. | ||
EGRESS PRE | Rescue crewmember to unzip and open PRE once airlock is pressurized. Crewmember egress from PRE. Remove O2 mask. | ||
PRE — DISCONNECT AUX O2 (if reqd) | Disconnect PRE from EMU or supplemental O2 canister if required. |